Last updated:

Electrical Objects

GorkyCAD’s electrical objects are not just symbols — they are intelligent engineering entities with properties that drive calculations.

Available Objects

ObjectHotkeyProperties
Power OutletORated current, height, group, IP rating
Low-current OutletShift+OType (RJ45/TV/phone), height
SwitchSSingle/double/pass-through, height
LightLPower, luminous flux, IP rating, height
Junction BoxJType, size
PanelPType (main/sub/floor/apartment), busbar rating

Placing Objects on Walls

Select an object, click on a wall. The object snaps automatically. Configure:

  • Installation height (default: outlets 300 mm, switches 900 mm, lights on ceiling)
  • Offset from wall corner (snap distance configurable)

Free Placement

Hold Ctrl while clicking to place an object freely (not on a wall) — useful for kitchen islands or open-plan areas.

Group Assignment

Each outlet/light belongs to a group connected to a specific breaker. Assign groups:

  • Manually: select objects and set group number
  • Automatically: GorkyCAD suggests optimal grouping based on load and room layout