Russian adoption of IEC 60364-7-701: zones 0–3, 30 mA RCDs, IPX4/IPX7.
| Document | GOST R 50571.7.701 Bathrooms |
| Edition | актуальные редакции |
| Status | Current (GOST R 50571.7.701) |
| Issued by | Rosstandart (adoption of IEC 60364-7-701) |
| Applies to | Rooms with baths and showers: zones 0–3 |
| № | Chapter / section |
|---|---|
| 701.30 | Zones |
| 701.41 | Shock protection |
| 701.512–701.55 | Equipment |
Zone 0 — bath volume; 1 — to 2.25 m; 2 — 0.6 m around; 3 — 2.4 m.
30 mA RCD or SELV for all circuits; supplementary bonding (701.415).
IPX7 zone 0; IPX4 zones 1–2; no sockets in zones 0–1.
Automatic single-line diagrams, PUE/GOST/IEC calculations, specification and PDF — from one model.
Start freeData is for reference. Final design decisions must follow current regulations and a qualified engineer.