--- Skip to content
Design 2025-06-08 · 8 min

Bathroom and Wet Area Electrical — Rules

Integrating pulse-output meters into your design. Connection diagrams, CT selection, AMR system based on GorkyCAD.

Author: GorkyCAD Team

Zones 0-2

Zone 0 — inside the bath/shower (IPX7, SELV 12 V). Zone 1 — above the bath (IPX4). Zone 2 — 60 cm from the bath (IPX4). Beyond zone 2 — normal requirements.

Sockets

Sockets — only in zone 2 and beyond, at least 60 cm from the water. All bathroom sockets — RCD 10 mA or 30 mA (10 mA recommended per IEC for children's protection).

Equipment

Heated towel rail — own circuit; washing machine — own circuit; boiler — own circuit. Each with its own MCB.

Lighting

Ceiling light in zones 1-2 — IPX4 minimum. LED strips above the mirror — SELV 12/24 V with a driver outside the zone.

Heated floor

In the bathroom — 150-200 W/m², own circuit, thermostat outside zone 2, RCD 10-30 mA.

GorkyCAD checks

Draws the zones on the plan, checks the placement of sockets and IP — the 41 checks find the mistakes before installation.