Kitchen Electrical Design

Integrating pulse-output meters into your design. Connection diagrams, CT selection, AMR system based on GorkyCAD.

Author: GorkyCAD Team

Dedicated circuits

Oven — own circuit (3-4 kW → 2.5-4 mm², C20-C25). Hob — own (7 kW → 6 mm², C32). Washer + dishwasher — separate circuits. Each with RCD 30 mA.

Socket planning

10+ sockets: work zone above the counter (every 60 cm), for appliances (fridge, microwave, hood, kettle), dining zone. In the cabinet — for dishwasher and washing machine.

Lighting layers

General light, work zone under the upper cabinets, hood lighting, dining pendant. Scenes are convenient: work/guest.

Ventilation

Hood — power and control circuit; range hoods with motor need a dedicated circuit.

Water safety

Sockets above the sink — no; RCD 10 mA near water; all work zone sockets — with shutters.

Why a project

Rewiring a kitchen after the cabinets are installed is impossible. The project fixes the sockets at the right heights before the walls close.