Isitish kabeli yoki matlarning quvvatini, kontur uzunligini, yotqizish qadamini, ta'minot kabelining kesimini va avtomat o'chirgich nominalini hisoblang — xona turi, pol qoplamasi va PUE talablari inobatga olingan holda.

Kalkulyator nimani hisoblaydi

  • Xona turi va pol qoplamasiga qarab talab etiladigan solishtirma quvvat (Vt/m²)
  • Konturning umumiy o'rnatilgan quvvati — vatt va kilovattlarda
  • Isitish kabelining uzunligi yoki isitish matlarining maydoni
  • Kabelni yotqizish qadami — santimetrlarda
  • Liniyaning hisobiy toki va avtomat o'chirgich nominali
  • RCD (30 mA) talabi va termoregulyator tanlash

Issiqlik pol quvvatini qanday tanlash kerak

Solishtirma quvvat (Vt/m²) loyihalashning asosiy parametridir. Turar joy xonalarida qulay isitish uchun 100–140 Vt/m², radiatorsiz to'liq isitish uchun 150–180 Vt/m² yetarli. Hammom va sanitariya tugunlarida me'yorlar yuqoriroq: qulay rejimda 140–150 Vt/m², chunki plitka jadalroq isitishni talab qiladi.

Yodda tuting: isitish kabeli yoki mat faqat bo'sh maydonga yotqiziladi — oyoqsiz mebel va statsionar santexnika ostiga yotqizish taqiqlanadi. Bu ham haddan tashqari qizish, ham ishlab chiqaruvchining bevosita taqiqidir (kafolat bekor qilinadi).

Kabel tizimlari uchun (styajkadagi isitish kabeli) 8–12 sm yotqizish qadami bilan 110–140 Vt/m² solishtirma quvvatni tanlang. Isitish matlarining quvvati ishlab chiqaruvchi tomonidan belgilanadi (odatda 150–220 Vt/m²) va maydonga qarab tanlanadi. Plyonkali infraqizil pollar 150–220 Vt/m² beradi va faqat laminat, linoleum yoki gilam ostiga, styajkasiz yotqiziladi.

Toshkent iqlimida qishning hisobiy harorati taxminan −12…−14 °C, shuning uchun ko'pchilik xonadonlarda 130–150 Vt/m² quvvatli mat tizimi xonalarni to'liq isitishga qodir. Samarqand va Navoiy viloyatlarida ham shu ko'rsatkich yetarli, lekin qishloq uylari uchun 150–180 Vt/m² zaxirani olish tavsiya etiladi.

Hisoblash formulalari

Hisoblash oddiy nisbatlarga asoslanadi:

1. Konturning talab etiladigan issiqlik quvvati: Q = S_foydali × q_solishtirma, bunda S_foydali — bo'sh pol maydoni (m²), q_solishtirma — solishtirma quvvat (Vt/m²).

2. Isitish kabelining uzunligi: L = S_foydali × 1000 / P_chiziqli, bunda P_chiziqli — kabelning chiziqli quvvati (odatda 16–20 Vt/m).

3. Kabelni yotqizish qadami: h = (P_chiziqli / q_solishtirma) × 100, sm. q = 130 Vt/m² va 17 Vt/m kabel uchun qadam taxminan 13 sm bo'ladi.

4. Liniyaning hisobiy toki: I = P / U (bir fazali 230 V tarmoq uchun), uch fazali uchun I = P / (√3 × U).

5. Avtomat nominali: I_avt ≥ 1,25 × I_hisobiy — standart qator 6, 10, 13, 16, 20, 25 A. 3,5 kVt gacha quvvat uchun bitta liniyada odatda C16 avtomati va 2,5 mm² kabel yetarli.

Q = S_foydali × q_solishtirma; L = S_foydali × 1000 / P_chiziqli; h = (P_chiziqli / q_solishtirma) × 100; I = P / U (bir faza), I = P / (√3 × U) (uch faza)

Xonalar bo'yicha solishtirma quvvat jadvali

XonaQulay rejim, Vt/m²To'liq isitish, Vt/m²Qoplama
Hammom / sanitariya tuguni140–150180Plitka, keramogranit
Oshxona120–140170Plitka / laminat
Yo'lak / koridor120–130160Plitka / laminat
Yotoqxona100–120160Laminat / parket
Mehmonxona100–120160Laminat / parket
Balkon / lodjiya140–160200Plitka

Me'yoriy baza

Issiqlik pollarini loyihalash PUE (1.1 va 7.1-boblar), СП 256.1325800 «Turar joy va jamoat binolarining elektr qurilmalari», СП 60.13330 «Isitish, ventilyatsiya va konditsionerlash» hamda СП 50.13330 (issiqlik himoyasi) hujjatlari bilan tartibga solinadi. MDH mamlakatlarida bu me'yorlar asosiy normativ baza hisoblanadi. Asosiy talablar:

— issiqlik pol konturi taqsimlash qalqonidan alohida liniya bilan ta'minlanadi va ishga tushish toki 30 mA dan oshmaydigan RCD bilan himoyalanadi;

— pol sirtining ruxsat etilgan harorati: doimiy bo'lish zonalarida 26 °C, hammom va xona chetlarida 31 °C (СП 60.13330);

— styajkadagi isitish kabeli faqat kabel kanallarida yoki armatura bilan yotqiziladi — izolyatsiya bilan bevosita aloqa bo'lmasligi kerak;

— termoregulyator majburiy: usiz pol haddan tashqari qiziydi, sarf oshadi va kabel ishdan chiqadi.

Kalkulyatordan qanday foydalanish kerak

  1. Xona turini tanlang (hammom, oshxona, yotoqxona va h.k.) — kalkulyator tavsiya etilgan solishtirma quvvatni avtomatik qo'yadi.
  2. Xona maydonini m² da va bo'sh maydon ulushini kiriting (odatda 70%).
  3. Tizim turini tanlang: isitish kabeli, isitish mati yoki IQ-plyonka.
  4. «Hisoblash» tugmasini bosing va quvvat, uzunlik, yotqizish qadami, tok, avtomat, RCD hamda termoregulyator talablarini oling.

O'rnatishda tez-tez uchraydigan xatolar

  • Mebel va santexnika ostiga yotqizish — kabelning qizib ishdan chiqishi, kafolatning bekor bo'lishi.
  • Termoregulyatorning yo'qligi — 30–50% ortiqcha elektr sarfi va qoplamaning qizishi.
  • Unutilgan RCD — kabel shikastlanganda elektr toki urishi mumkin.
  • Yotqizish qadamining 8 sm dan kam bo'lishi — kabelning styajkada mahalliy qizishi.
  • Yupqa styajka (kabel ustida 3 sm dan kam) — yoriqlar va notekis isitish.
  • Quvvatni mebelni hisobga olmasdan butun maydon bo'yicha hisoblash — real issiqlik hisoblanganidan kam.

Issiqlik pol haqida tez-tez beriladigan savollar

Issiqlik pol qancha elektr energiyasi sarflaydi?

Qulay rejimda — sutkada o'rtacha 10–20 Vt/m² (termoregulyatorning ishlash davrlari hisobga olingan holda). 20 m² xonani to'liq isitish issiqlik yo'qotishiga qarab kuniga 1,5–2,5 kVt·soat sarflaydi. Pol va havo sensorli aqlli termostatlar sarfni 30–40% kamaytiradi.

Issiqlik polni asosiy isitish sifatida ishlatish mumkinmi?

Ha, agar solishtirma quvvat 150–180 Vt/m² bo'lsa va xonaning issiqlik yo'qotishi tanlangan quvvatdan oshmasa. Yaxshi izolyatsiyalangan 60–80 m² gacha bo'lgan xonadonlarda kabel pol radiatorlarni to'liq almashtira oladi. Issiqlik yo'qotishini hisoblash majburiy — issiqlik yo'qotish kalkulyatoridan foydalaning.

Nega mebel ostiga kabel yotqizib bo'lmaydi?

Oyoqsiz mebel issiqlik berishni to'sadi, kabel qobiq uchun ruxsat etilgan 90 °C dan yuqori qiziydi, styajka yoriladi va ishlab chiqaruvchining kafolati bekor bo'ladi. Plyonkali pollar ham mebel ostiga yotqizilishi mumkin emas.

Issiqlik polga qanday avtomat o'rnatiladi?

3,5 kVt gacha bo'lgan liniya uchun — 30 mA RCD bilan C16 avtomati, VVGng-LS 3×2,5 mm² sim. 3,5–5,5 kVt quvvat uchun — har biri 16 A dan alohida konturlar yoki 4 mm² kabel bilan C25 avtomati. Aniq hisobni kalkulyator beradi.

Isitish kabeli va mat o'rtasidagi farq nima?

Kabel ixtiyoriy qadam bilan styajkaga yotqiziladi va murakkab konfiguratsiyalar uchun mos keladi, lekin 3–5 sm styajka talab qiladi. Mat — to'r ustidagi kabel, styajkasiz plitka yopishtiruvchi qatlamiga yotqiziladi, polning ko'tarilishi minimal. Plyonka — laminat/linoleum ostiga, styajkasiz, lekin albatta tagida izolyatsiya bilan.

Issiqlik polni o'rnatish uchun ruxsat kerakmi?

Xonadonda — yukni oshiradigan ishlar uchun boshqaruv kompaniyasi bilan kelishish talab etiladi (СП 256.1325800, 8.12-band). Xususiy uyda ruxsat talab qilinmaydi, lekin PUE bo'yicha loyihalash majburiy.

🔌 Barcha vositalar

(function(){ var T={ az:{t:"İsti döşəmə kalkulyatoru",room:"Otaq növü",area:"Otaq sahəsi (m²)",free:"Sərbəst sahə (%)",sys:"Sistem növü",cable:"İstilik kabeli (17 Vt/m)",mat:"İstilik matı (160 Vt/m²)",film:"İQ film (200 Vt/m²)",calc:"Hesabla",res:"Nəticə",pwr:"Quvvət",len:"Kabel uzunluğu",step:"Döşəmə addımı",cur:"Cərəyan",brk:"Avtomat",sec:"Kəsiyi",rcd:"UZO 30 mA TƏLƏB OLUNUR",stat:"Termostat 16 A (3,5 kVt-a qədər)",bath:"Hamam",kitchen:"Mətbəx",hall:"Dəhliz",bed:"Yataq otağı",living:"Qonaq otağı",balcony:"Balkon",note:"Hesablama PUE və SP 256 əsasında"}, be:{t:"Калькулятар цёплай падлогі",room:"Тып памяшкання",area:"Плошча памяшкання (м²)",free:"Свабодная плошча (%)",sys:"Тып сістэмы",cable:"Грэючы кабель (17 Вт/м)",mat:"Грэючы мат (160 Вт/м²)",film:"ІЧ-плёнка (200 Вт/м²)",calc:"Разлічыць",res:"Вынік",pwr:"Магутнасць",len:"Даўжыня кабеля",step:"Крок укладкі",cur:"Ток",brk:"Аўтамат",sec:"Перачын",rcd:"ПАТРЭБНА ЎЗО 30 мА",stat:"Тэрмарэгулятар 16 А (да 3,5 кВт)",bath:"Ванная",kitchen:"Кухня",hall:"Калідор",bed:"Спальня",living:"Гасцёўня",balcony:"Балкон",note:"Разлік па ПУЭ і СП 256"}, de:{t:"Fußbodenheizung-Rechner",room:"Raumtyp",area:"Raumfläche (m²)",free:"Freie Fläche (%)",sys:"Systemtyp",cable:"Heizkabel (17 W/m)",mat:"Heizmatte (160 W/m²)",film:"IR-Folie (200 W/m²)",calc:"Berechnen",res:"Ergebnis",pwr:"Leistung",len:"Kabellänge",step:"Verlegeabstand",cur:"Strom",brk:"Sicherung",sec:"Querschnitt",rcd:"RCD 30 mA ERFORDERLICH",stat:"Thermostat 16 A (bis 3,5 kW)",bath:"Bad",kitchen:"Küche",hall:"Flur",bed:"Schlafzimmer",living:"Wohnzimmer",balcony:"Balkon",note:"Berechnung nach IEC 60364 und VDE"}, en:{t:"Underfloor Heating Calculator",room:"Room type",area:"Room area (m²)",free:"Usable area (%)",sys:"System type",cable:"Heating cable (17 W/m)",mat:"Heating mat (160 W/m²)",film:"IR film (200 W/m²)",calc:"Calculate",res:"Result",pwr:"Power",len:"Cable length",step:"Cable spacing",cur:"Current",brk:"Breaker",sec:"Cable",rcd:"RCD 30 mA REQUIRED",stat:"Thermostat 16 A (up to 3.5 kW)",bath:"Bathroom",kitchen:"Kitchen",hall:"Hallway",bed:"Bedroom",living:"Living room",balcony:"Balcony",note:"Calculation per IEC 60364"}, hi:{t:"अंडरफ्लोर हीटिंग कैलकुलेटर",room:"कमरे का प्रकार",area:"कमरे का क्षेत्रफल (m²)",free:"प्रयोग योग्य क्षेत्र (%)",sys:"सिस्टम प्रकार",cable:"हीटिंग केबल (17 W/m)",mat:"हीटिंग मैट (160 W/m²)",film:"IR फिल्म (200 W/m²)",calc:"गणना करें",res:"परिणाम",pwr:"पावर",len:"केबल लंबाई",step:"केबल स्पेसिंग",cur:"करंट",brk:"MCB",sec:"पार",rcd:"RCD 30 mA आवश्यक",stat:"थर्मोस्टेट 16 A (3.5 kW तक)",bath:"बाथरूम",kitchen:"रसोई",hall:"हॉलवे",bed:"बेडरूम",living:"लिविंग रूम",balcony:"बालकनी",note:"गणना IEC 60364 अनुसार"}, hy:{t:"Հատակային ջեռուցման հաշվիչ",room:"Սենյակի տեսակ",area:"Սենյակի մակերես (մ²)",free:"Ազատ մակերես (%)",sys:"Համակարգի տեսակ",cable:"Ջեռուցման մալուխ (17 Վտ/մ)",mat:"Ջեռուցման գորգ (160 Վտ/մ²)",film:"ԻՌ թաղանթ (200 Վտ/մ²)",calc:"Հաշվել",res:"Արդյունք",pwr:"Հզորություն",len:"Մալուխի երկարություն",step:"Քայլ",cur:"Հոսանք",brk:"Ավտոմատ",sec:"Խաչաձև կտրվածք",rcd:"ՊԱՀԱՆՋՎՈՒՄ Է ՈՒԶՕ 30 մԱ",stat:"Թերմոստատ 16 Ա (մինչև 3,5 կՎտ)",bath:"Լոգարան",kitchen:"Խոհանոց",hall:"Միջանցք",bed:"Ննջասենյակ",living:"Հյուրասենյակ",balcony:"Պատշգամբ",note:"Հաշվարկը՝ ըստ IEC 60364"}, ka:{t:"გამაცხელებელი იატაკის კალკულატორი",room:"ოთახის ტიპი",area:"ოთახის ფართობი (მ²)",free:"თავისუფალი ფართობი (%)",sys:"სისტემის ტიპი",cable:"გამათბობელი კაბელი (17 ვტ/მ)",mat:"გამათბობელი ხალიჩა (160 ვტ/მ²)",film:"ირ ფირი (200 ვტ/მ²)",calc:"გამოთვლა",res:"შედეგი",pwr:"სიმძლავრე",len:"კაბელის სიგრძე",step:"დაგების საფეხური",cur:"დენი",brk:"ავტომატი",sec:"კვეთა",rcd:"საჭიროა უიზო 30 მა",stat:"თერმოსტატი 16 ა (3,5 კვტ-მდე)",bath:"აბაზანა",kitchen:"სამზარეულო",hall:"დერეფანი",bed:"საძინებელი",living:"მისაღები",balcony:"აივანი",note:"გამოთვლა IEC 60364-ით"}, kk:{t:"Жылы еден калькуляторы",room:"Бөлме түрі",area:"Бөлме ауданы (м²)",free:"Бос аудан (%)",sys:"Жүйе түрі",cable:"Жылыту кабелі (17 Вт/м)",mat:"Жылыту төсеніші (160 Вт/м²)",film:"ИК пленка (200 Вт/м²)",calc:"Есептеу",res:"Нәтиже",pwr:"Қуат",len:"Кабель ұзындығы",step:"Төсеу қадамы",cur:"Ток",brk:"Автомат",sec:"Қимасы",rcd:"УЗО 30 мА ТАЛАП ЕТІЛЕДІ",stat:"Термостат 16 А (3,5 кВт дейін)",bath:"Жуынатын бөлме",kitchen:"Ас үй",hall:"Дәліз",bed:"Жатын бөлме",living:"Қонақ бөлме",balcony:"Балкон",note:"Есептеу ПУЭ және СП 256 бойынша"}, ky:{t:"Жылуу пол калькулятору",room:"Бөлмөнүн түрү",area:"Бөлмөнүн аянты (м²)",free:"Бош аянт (%)",sys:"Системанын түрү",cable:"Жылытуу кабели (17 Вт/м)",mat:"Жылытуу тобокели (160 Вт/м²)",film:"ИК пленка (200 Вт/м²)",calc:"Эсептөө",res:"Жыйынтык",pwr:"Кубат",len:"Кабелдин узундугу",step:"Төшөө кадамы",cur:"Ток",brk:"Автомат",sec:"Кесилиши",rcd:"УЗО 30 мА КЕРЕК",stat:"Термостат 16 А (3,5 кВт чейин)",bath:"Ванна",kitchen:"Ашкана",hall:"Коридор",bed:"Уктоочу бөлмө",living:"Күнүмдүк бөлмө",balcony:"Балкон",note:"Эсептөө ПУЭ жана СП 256 боюнча"}, pl:{t:"Kalkulator ogrzewania podłogowego",room:"Typ pomieszczenia",area:"Powierzchnia (m²)",free:"Powierzchnia użytkowa (%)",sys:"Typ systemu",cable:"Kabel grzejny (17 W/m)",mat:"Mata grzewcza (160 W/m²)",film:"Folia IR (200 W/m²)",calc:"Oblicz",res:"Wynik",pwr:"Moc",len:"Długość kabla",step:"Rozstaw",cur:"Prąd",brk:"Wyłącznik",sec:"Przekrój",rcd:"WYMAGANY RCD 30 mA",stat:"Termostat 16 A (do 3,5 kW)",bath:"Łazienka",kitchen:"Kuchnia",hall:"Przedpokój",bed:"Sypialnia",living:"Salon",balcony:"Balkon",note:"Obliczenia wg IEC 60364"}, ro:{t:"Calculator încălzire în pardoseală",room:"Tipul camerei",area:"Suprafața (m²)",free:"Suprafața utilă (%)",sys:"Tipul sistemului",cable:"Cablu termic (17 W/m)",mat:"Placă termică (160 W/m²)",film:"Folie IR (200 W/m²)",calc:"Calculează",res:"Rezultat",pwr:"Putere",len:"Lungime cablu",step:"Pas de montaj",cur:"Curent",brk:"Întrerupător",sec:"Secțiune",rcd:"RCD 30 mA OBLIGATORIU",stat:"Termostat 16 A (până la 3,5 kW)",bath:"Baie",kitchen:"Bucătărie",hall:"Hol",bed:"Dormitor",living:"Sufragerie",balcony:"Balcon",note:"Calcul conform IEC 60364"}, ru:{t:"Калькулятор тёплого пола",room:"Тип помещения",area:"Площадь помещения (м²)",free:"Свободная площадь (%)",sys:"Тип системы",cable:"Греющий кабель (17 Вт/м)",mat:"Нагревательный мат (160 Вт/м²)",film:"ИК-плёнка (200 Вт/м²)",calc:"Рассчитать",res:"Результат",pwr:"Мощность",len:"Длина кабеля",step:"Шаг укладки",cur:"Ток",brk:"Автомат",sec:"Сечение",rcd:"ТРЕБУЕТСЯ УЗО 30 мА",stat:"Терморегулятор 16 А (до 3,5 кВт)",bath:"Ванная",kitchen:"Кухня",hall:"Коридор",bed:"Спальня",living:"Гостиная",balcony:"Балкон",note:"Расчёт по ПУЭ и СП 256"}, tg:{t:"Калкулятори гармии фарш",room:"Навъи ҳуҷра",area:"Масоҳати ҳуҷра (м²)",free:"Масоҳати озод (%)",sys:"Навъи система",cable:"Кабели гармидиҳӣ (17 Вт/м)",mat:"Палоси гармидиҳӣ (160 Вт/м²)",film:"Плёнкаи инфрасурх (200 Вт/м²)",calc:"Ҳисоб кардан",res:"Натиҷа",pwr:"Қувва",len:"Дарозии кабел",step:"Қадами гузоштан",cur:"Ҷараён",brk:"Автомат",sec:"Буриш",rcd:"УЗО 30 мА ЗАРУР",stat:"Термостат 16 А (то 3,5 кВт)",bath:"Ҳаммом",kitchen:"Ошхона",hall:"Долон",bed:"Хобгоҳ",living:"Меҳмонхона",balcony:"Балкон",note:"Ҳисоб аз рӯи ПУЭ ва СП 256"}, uz:{t:"Issiqlik pol kalkulyatori",room:"Xona turi",area:"Xona maydoni (m²)",free:"Bo'sh maydon (%)",sys:"Tizim turi",cable:"Isitish kabeli (17 Vt/m)",mat:"Isitish mati (160 Vt/m²)",film:"IQ plyonka (200 Vt/m²)",calc:"Hisoblash",res:"Natija",pwr:"Quvvat",len:"Kabel uzunligi",step:"Yotqizish qadami",cur:"Tok",brk:"Avtomat",sec:"Kesim",rcd:"UZO 30 mA TALAB QILINADI",stat:"Termostat 16 A (3,5 kVt gacha)",bath:"Hammom",kitchen:"Oshxona",hall:"Koridor",bed:"Yotoq xonasi",living:"Mehmonxona",balcony:"Balkon",note:"Hisoblash PUE va SP 256 bo'yicha"} }; var L=document.documentElement.lang;var t=T[L]||T.en; var S=document.createElement('div'); S.innerHTML='

'+t.t+'

'+ '
'+ '
'+ '
'+ '
'+ '
'+ ''+ '
'; var h=document.querySelector('main');if(!h)return;var sect=h.querySelector('.section');if(!sect)return;sect.parentNode.insertBefore(S,sect.nextSibling); document.getElementById('wf-go').onclick=function(){ var q=+document.getElementById('wf-room').value,area=+document.getElementById('wf-area').value,free=+document.getElementById('wf-free').value,sys=document.getElementById('wf-sys').value; var su=area*free/100; var Q=Math.round(su*q/10)*10; var lin=sys==='cable'?17:0; var Ln=Math.round(su*1000/lin); var step=sys==='cable'?Math.round(lin/q*100):null; var I=Q/230; var brk=I>22.7?32:(I>16.4?25:(I>13.6?20:(I>10.9?16:(I>6.8?10:6)))); var sec=I>16.4?'6 mm²':(I>10.9?'4 mm²':(I>6.8?'2.5 mm²':'1.5 mm²')); var warn=Q>3500?'⚠ >3.5 kW — split into separate circuits
':''; var o=''+t.res+'
'+t.pwr+': '+Q+' W ('+(Q/1000).toFixed(2)+' kW)
'; if(sys==='cable')o+=t.len+': '+Ln+' m · '+t.step+': '+step+' cm
'; else o+=t.len+': '+su.toFixed(1)+' m²
'; o+=t.cur+': '+I.toFixed(1)+' A · '+t.brk+': C'+brk+' · '+t.sec+': '+sec+'
'+warn; o+=''+t.rcd+'
'+t.stat+' · '+t.note+''; document.getElementById('wf-out').innerHTML=o; };})();