Marketpleys Sim o'tkazish narxi Usta topish Ustalar uchun ish Muharrirni ochish
Bosh sahifa

Selectivity: breakers that work together

Selectivity means only the faulty circuit trips, not the whole floor. GorkyCAD checks the chain: input breaker → floor → group → socket — and shows where selectivity fails.

📐 Floor Plan & Rooms

🧱

Walls & Partitions

Load-bearing and non-load-bearing walls, partitions, thickness and material settings.

🚪

Doors & Windows

Door and window placement, size configuration, opening direction.

📏

Dimensions & Annotations

Automatic dimensions, callouts, text annotations on the plan.

📦

DXF Import

Import floor plans from AutoCAD and other CAD systems via DXF.

Electrical

Outlets & Switches

Power and low-current outlets, switches, dimmers. GOST/IS symbols.

💡

Lighting

Luminaires, lighting groups, automatic illuminance calculation.

📫

Junction Boxes

Automatic junction box placement, connection count accounting.

📋

GOST/PUE/IS Symbols

Complete library of symbols per GOST, PUE, IS, IEC standards.

🔲 Panels

🗄️

Auto Panel Assembly

Automatic panel layout: MCBs, RCDs, RCBOs, isolators — from the schematic.

📏

DIN Rails & Busbars

Automatic DIN rail length calculation, auto busbars per phase.

🌐

Feeder Topology

Panel hierarchy: main → sub → floor → apartment. Automatic connectivity.

〰️ Cables & Routes

🗺️

Auto Routing

Automatic cable routing via shortest path with obstacle avoidance.

📐

Cable Sizing

Automatic cross-section calculation by heating, voltage drop, short-circuit current.

📊

Cable Schedule

Automatic cable schedule generation with types, lengths, routes.

⬇️

Voltage Drop

Voltage drop calculation along the entire chain: from main panel to end consumer.

📊 Calculations

Loads

Pinst, Pcalc, Icalc, cos φ, Kd — automatic per IEC/IS standards.

🔥

Short-Circuit

Single-phase and three-phase short-circuit current calculation, breaker verification.

🔗

Selectivity

Protection selectivity check: upstream/downstream breaker coordination.

Deterministic Engine

All calculations are deterministic, not LLM. Guaranteed repeatability.

📄 Documents

📑

PDF Complete Set

Plan, single-line diagram, panel schematic, BOM, cable schedule, estimate — one click.

📐

DXF Export

Export plans and schematics to DXF for compatibility with AutoCAD and other CAD.

📊

Bill of Materials

Automatic bill of materials with equipment, cables and materials quantities.

💰

Estimate

Automatic cost calculation for equipment, cables, and installation work.

🤖 AI Assistant

Standards Checking

Automatic project check against GOST, PUE, IS, IEC with violation details.

💡

Recommendations

AI suggests fixes for errors and project optimizations.

Calculation Explanations

Step-by-step explanation of each calculation: formulas, inputs, results.

🔍

Project Search

Semantic project search: find all outlets in the bedroom, check cable size in the kitchen.

🏗️ 3D Visualization

3D Building Model

Automatic 3D building model from floor plan: walls, doors, windows.

3D Cable Routes

3D cable route visualization with color-coded groups.

🗄️

3D Panel

Three-dimensional panel visualization with DIN rails and devices.

And this is just the beginning. New features are added every week.

🌐 Open app 🚀 Try for free

How it works

  • GorkyCAD builds the protection chain from your panel;
  • Compares ratings and tripping curves (B/C/D);
  • Flags zones without selectivity — you fix before installation.

FAQ

Why is selectivity important?
Without it, one faulty socket turns off the whole house or floor. With selectivity — only the damaged circuit.
What curves are supported?
B, C, D trip curves with current and time coordination.

Selektivlik kalkulyatori

Himoya qurilmalarining selektiv muvofiqlashtirishini tekshiring: yuqori va pastki avtomatlar jufti, 1,6× qoidasi, xarakteristikalar kesishishini tahlil qilish va S tipidagi RCD muvofiqlashtirish — faqat shikastlangan liniya uzilishi uchun.

Kalkulyator nimani hisoblaydi

Selektivlik (tanlash xususiyati) — qisqa tutashuv yoki haddan tashqari yuklamada faqat shikastga eng yaqin himoya qurilmasi ishga tushishi. Selektivlik buzilganda yuqori avtomat ham ishlaydi va butun ob'ekt (masalan, butun xonadon) quvvatsiz qoladi, garchi faqat bitta liniya shikastlangan bo'lsa ham.

Kalkulyator «pastki–yuqori» jufti parametrlarini tekshiradi. Amaliy qoida: yuqori avtomatning nominali pastkinikidan kamida 1,6 baravar katta bo'lishi kerak (I_yuqori ≥ 1,6 × I_pastki). Bundan tashqari, xarakteristikalar (B/C/D) hisobga olinadi: bir xil xarakteristikada 1,6 koeffitsiyenti ishonchli ishlaydi, har xil xarakteristikalarda esa vaqt-tok xarakteristikalarining kesishishini tekshirish kerak.

RCD lar selektivligi alohida tekshiriladi: yuqori RCD ning uzish toki pastkinikidan kamida 3 baravar katta bo'lishi va S tipida (vaqt kechikishli) bo'lishi kerak: masalan, 30 mA → 100 mA S tipi. Bu kirishdagi yong'indan himoya RCD guruh RCD dan keyin ishga tushishini oldini oladi.

Kalkulyatorning xususiyatlari

  • Avtomat juftini tekshirish: I_yuqori ≥ 1,6 × I_pastki
  • Xarakteristikalar (B/C/D) muvofiqligini hisobga olish
  • Vaqt-tok xarakteristikalarining kesishishini tahlil qilish
  • RCD muvofiqlashtirish: IΔn_yuqori ≥ 3 × IΔn_pastki
  • Selektiv S tipidagi RCD tavsiyasi
  • Kesishish zonalarida avariya himoyasi bo'yicha tavsiyalar
  • PUE 3.1 va IEC 60947 talablariga muvofiqlik

Hisoblash formulalari

Avtomatlarning asosiy qoidasi: I_yuqori ≥ 1,6 × I_pastki — bir xil xarakteristikada (masalan, ikkalasi ham C). Qoida shuni anglatadiki, yuqori avtomatning termik bo'shatishi pastkinikining maksimal ishga tushish tokidan keyinroq ishlaydi.

Xarakteristikalar farq qilganda qoida qat'iylashadi: B va C jufti uchun minimal nisbat 1,6 emas, 2 qabul qilinadi, chunki C xarakteristikasining ishga tushish diapazoni B dan yuqori.

RCD muvofiqlashtirish: IΔn_yuqori ≥ 3 × IΔn_pastki, masalan, 30 mA → 100 mA. Yuqori RCD S tipida bo'lishi kerak (vaqt kechikishi 40–300 ms).

Misol: xonadonda kirish avtomati 40 A (C), guruh liniyalari — 16 A (C). Nisbat 40/16 = 2,5 ≥ 1,6 — selektivlik ta'minlanadi. 25 A kirish va 16 A guruh uchun nisbat 25/16 = 1,56 < 1,6 — chegaraviy holat, xarakteristikalarni tekshirish kerak.

I_yuqori ≥ 1,6 × I_pastki; IΔn_yuqori ≥ 3 × IΔn_pastki (S tipi)

Avtomatlar muvofiqlashtirish jadvali (1,6× qoidasi)

Pastki avtomat, AMinimal yuqori, ATavsiya etiladigan, A
61010–16
101616–20
162525–32
203232–40
254040–50
325050–63
406363–80

Me'yoriy baza

Himoya qurilmalarining selektivligi PUE 3.1-bob (himoya qurilmalarini tanlash talablari), GOST R 50345-2010 (maishiy avtomatlar) va GOST R 50030.2 (IEC 60947-2) hujjatlari bilan tartibga solinadi. SP 256.1325800.2016 guruh tarmoqlarida himoya talablarini belgilaydi. Asosiy prinsiplar:

— zanjirli qurilmalarda har bir keyingi qurilma ishga tushish tokiga ko'ra selektiv bo'lishi kerak;

— to'liq selektivlikka erishib bo'lmasa, avariya himoyasi bilan qisman selektivlik ruxsat etiladi (vaqt kechikishi 0,4 s);

— RCD lar orasidagi selektivlik faqat yuqorida S tipidagi qurilma o'rnatilganda ta'minlanadi;

— avtomatlar tanlashda «yuqorida zaxira» prinsipi buzilmasligi kerak: yuqori avtomat pastki liniyaning kabelini ham himoya qilishi kerak.

Kalkulyatordan qanday foydalanish kerak

  1. Pastki (guruh) avtomatning nominali va xarakteristikasini kiriting.
  2. Yuqori (kirish) avtomatning nominali va xarakteristikasini ko'rsating.
  3. RCD lar bo'lsa, ikkala darajaning uzish toklarini kiriting.
  4. Liniya oxiridagi qisqa tutashuv tokini belgilang (aniq tekshirish uchun).
  5. «Hisoblash» tugmasini bosing va natijani oling: selektivlik ta'minlanganmi yoki yo'q, va tavsiyalar.

Tez-tez uchraydigan xatolar

  • Bir xil nominaldagi avtomatlarni ketma-ket o'rnatish — shikastda qaysi biri ishlashi noma'lum, ko'pincha yuqorisi ishlaydi.
  • Faqat nominallarni tekshirish, xarakteristikalarni hisobga olmaslik — B16 va C16 jufti selektiv emas.
  • Har ikki darajada bir xil IΔn li RCD lar — oqishda ishga tushish tasodifiy, ko'pincha kirish RCD ishlaydi.
  • Yuqori avtomatni haddan tashqari katta tanlash — pastki liniya kabeli himoyasiz qoladi.
  • Vaqt-tok xarakteristikalarining kesishishini hisobga olmaslik — katta toklarda selektivlik yo'qoladi.
  • Selektivlikni faqat qisqa tutashuv uchun tekshirish — haddan tashqari yuklama zonalarida ham ishga tushish tartibi buzilishi mumkin.

Selektivlik haqida tez-tez beriladigan savollar

Selektivlik oddiy so'zlar bilan nima?

Bu qisqa tutashuv yoki haddan tashqari yuklamada faqat shikastga eng yaqin himoya qurilmasi ishga tushishi. Masalan, oshxona rozetkasida qisqa tutashuv bo'lsa, faqat oshxona liniyasi avtomati o'chadi, butun xonadon yorug' bo'lib qoladi. Selektivlik bo'lmasa, kirish avtomati ham ishlaydi va butun xonadon quvvatsiz qoladi.

Nega aynan 1,6 koeffitsiyenti?

Avtomatning termik bo'shatish ishlash diapazoni nominalning 1,13× idan boshlanadi, elektromagnit bo'shatish esa xarakteristikaga bog'liq (C uchun 5–10×). 1,6 koeffitsiyenti yuqori avtomatning bo'shatish zonalari pastkinikining zonalariga tushmasligini va uning termik bo'shatishi doim kechikish bilan ishlashini ta'minlaydi. Kichikroq nisbatlarda ikkala avtomat bir vaqtda ishlashi mumkin.

RCD larni qanday muvofiqlashtirish mumkin?

Guruh RCD lari (30 mA) va kirishdagi yong'indan himoya RCD (100–300 mA) ikkita shartga amal qilishi kerak: birinchisi, uzish toklari nisbati kamida 3:1 bo'lishi (30 → 100 mA); ikkinchisi, yuqori RCD S tipida bo'lishi — 40–300 ms vaqt kechikishi bilan. Bu holda oqishda guruh RCD darhol ishlaydi, kirish RCD esa faqat guruh RCD shikastni uza olmasa.

Xarakteristikalar kesishsa nima qilish kerak?

Ikkita variant bor: xarakteristikalarni ajratish (masalan, pastda B, yuqorida C) — lekin bu har doim yetarli emas; yoki yuqorida vaqt kechikishli selektiv avtomatdan foydalanish (selektiv kategoriya, GOST R 50030.2 bo'yicha). Katta taqsimlash qurilmalarida mantiqiy selektivlik qo'llaniladi — qurilmalar orasidagi aloqa kanali bilan muvofiqlashtirish.

Xonadonda selektivlik muhimmi?

Ha. Xonadonda selektivlik buzilsa, masalan, choynakning qisqa tutashuvi kirish avtomatini ishga tushiradi — butun xonadon, jumladan yoritish va muzlatgich quvvatsiz qoladi. To'g'ri tanlov: kirish 40 A (C), guruh liniyalari 16–20 A (C), yoritish 10 A (B), RCD 100 mA S + guruh 30 mA. Bu sxema shikastlarning 90% ida faqat guruh avtomati ishlashini ta'minlaydi.

🔌 Barcha vositalar