Asboblar Marketpleys Sim o'tkazish narxi Usta topish Ustalar uchun ish Muharrirni ochish
Bosh sahifa
← All tools

Distribution Panel Builder

An interactive tool for laying out low-voltage distribution panels (DB, MDB, SDB). Allows you to place modular devices on DIN rails, verify enclosure fill ratio, calculate heat dissipation, and generate a bill of materials.

Automatically checks layout compliance with regulatory requirements for spare capacity (minimum 15% free space per PUE/IEC), protective device selectivity, and permissible internal temperature rise.

Features

  • Modular device placement on DIN rails
  • Automatic heat loss calculation inside the enclosure
  • Panel fill ratio control (minimum 15% reserve per standards)
  • Incoming breaker and RCD selection
  • Protective device selectivity verification
  • Single-line diagram generation
  • Bill of materials export to Excel/PDF

Standards

  • IEC 61439 — Low-voltage switchgear and controlgear assemblies
  • GOST R 51321.1 (IEC 60439-1) — LV switchgear assemblies
  • PUE — Russian Electrical Installation Code, Chapter 3.1

Launch Panel Builder →

Elektr qalqoni konstruktori

Taqsimlash qalqonini tuzing: DIN-reykada modul qurilmalarni joylashtiring, zaxira joylarni (kamida 15%) va issiqlik ajralishini tekshiring, bir chiziqli sxema va materiallar ro'yxatini yarating — IEC 61439 va PUE talablari bilan.

Konstruktor nimani hisoblaydi

Taqsimlash qalqonini loyihalash modul qurilmalarni (avtomatlar, RCD, difavtomatlar, hisoblagichlar) DIN-reykada joylashtirishdan boshlanadi. Bitta modulning eni 17,5 mm; xonadon qalqonida odatda 2–4 DIN-reyka va 18–36 modul joy bo'ladi. Har bir qurilma ma'lum miqdordagi modulni egallaydi: 1P avtomat — 1, 2P — 2, RCD 2P — 2, hisoblagich — 4–8 modul.

Konstruktor ikkita muhim tekshiruvni avtomatik amalga oshiradi. Birinchisi, zaxira joy: PUE va IEC 61439 talablariga ko'ra qalqonning bo'sh joylari kamida 15% bo'lishi kerak — kelajakdagi o'zgarishlar uchun. Ikkinchisi, issiqlik: barcha qurilmalar yo'qotishlarining yig'indisi (I² × R) qalqon ichidagi ruxsat etilgan harorat chegarasidan (muhitga nisbatan +30…40 °C dan oshmagan holda, IEC 61439 bo'yicha) oshmasligi kerak.

Konstruktor shuningdek kirish avtomati va RCD tanlashni tekshiradi, himoya qurilmalarining selektivligini baholaydi, bir chiziqli sxema yaratadi va materiallar ro'yxatini (BOM) Excel/PDF formatiga eksport qiladi.

Konstruktorning xususiyatlari

  • Modul qurilmalarni DIN-reykada joylashtirish
  • To'ldirish koeffitsiyentini avtomatik tekshirish (kamida 15% zaxira)
  • Qalqon ichida issiqlik yo'qotishini hisoblash
  • Kirish o'chirgichi va RCD tanlash
  • Himoya qurilmalarining selektivligini tekshirish
  • Bir chiziqli sxema yaratish
  • Materiallar ro'yxatini Excel/PDF ga eksport qilish

Hisoblash formulalari

Qalqonning umumiy modulligi: N_umumiy = Σ N_qurilma, bunda har qurilmaning modul soni eniga qarab aniqlanadi (1 modul = 17,5 mm). Xonadon qalqonlari uchun standart qator: 18, 24, 36, 48 modul.

Zaxira sharti: N_bo'sh ≥ 0,15 × N_band, ya'ni bo'sh modullar soni bandlarning kamida 15% i bo'lishi kerak. Masalan, 24 modulli qalqonda 20 qurilma moduli uchun zaxira 4 modul (16,7%) — shart bajariladi.

Qalqonning issiqlik ajralishi: Q = Σ (I_i² × R_i), bunda I_i — qurilmadan o'tadigan tok, R_i — bo'shatish va kontaktlar qarshiligi (har qutbga ≈ 0,5–2 mOm). Soddalashtirilgan baholash: nominal yuklamalarda har avtomat qutbi taxminan 1–2 Vt yo'qotish beradi.

Issiqlik tekshiruvi: Q ≤ Q_ruxsat, bunda Q_ruxsat — korpusning issiqlik o'tkazishiga ko'ra ruxsat etilgan yo'qotish quvvati (korpus o'lchami va materialiga bog'liq, odatda 30–100 Vt).

N_bo'sh ≥ 0,15 × N_band; Q = Σ I²·R (R ≈ 0,5–2 mOm/qutb)

Modul qurilmalarning modulligi jadvali

QurilmaModullar soniTipik qo'llanish
Avtomat 1P (B/C/D)1Yoritish, rozetka liniyalari
Avtomat 2P2Bir fazali kirish, suv isitgichi
Avtomat 3P3Uch fazali yuklamalar, plita
RCD 2P2Guruh himoyasi (30 mA)
Difavtomat 1P+N2RCD + avtomat bitta qurilmada
Hisoblagich (maishiy)4–8Energiya hisobi

Me'yoriy baza

Taqsimlash qalqonlarini loyihalash GOST R 51321.1 (IEC 60439-1) va IEC 61439-1/-2 «Past kuchlanishli taqsimlash qurilmalari», PUE 3.1-bob va SP 256.1325800.2016 hujjatlari bilan tartibga solinadi. Asosiy talablar:

— qalqonning bo'sh joylari kamida 15% bo'lishi kerak (PUE va IEC 61439 talabi);

— qalqon ichidagi harorat o'sishi IEC 61439 bo'yicha ruxsat etilgan chegaradan oshmasligi kerak;

— kirish qurilmasi hisobiy yuklamaga qarab tanlanadi va hisoblagichdan keyin o'rnatiladi;

— qalqonning metall korpusi PE o'tkazgich bilan albatta tuproqlanishi kerak;

— qurilmalarning bir chiziqli sxemasi GOST 21.613 talablariga muvofiq tuziladi.

Konstruktordan qanday foydalanish kerak

  1. Qalqon turini tanlang: xonadon, xususiy uy, ofis yoki sanoat.
  2. Barcha zanjirlarni qo'shing: nomi, avtomat nominali, RCD talabi.
  3. Qurilmalarni DIN-reykada joylashtiring — konstruktor modullarni hisoblaydi.
  4. «Tekshirish» tugmasini bosing: zaxira joy va issiqlik tekshiruvi natijasini oling.
  5. Bir chiziqli sxema va materiallar ro'yxatini eksport qiling.

Tez-tez uchraydigan xatolar

  • Zaxira modullarning yo'qligi — qalqonga o'zgartirish uchun joy yo'q, qalqonni almashtirishga to'g'ri keladi.
  • Issiqlikni hisoblamaslik — yopiq qalqonlarda qurilmalar haddan tashqari qiziydi, bo'shatishlar noto'g'ri ishlaydi.
  • RCD bilan himoyalangan liniyalarni guruhlamaslik — sxemani ta'mirlashda chalkashlik paydo bo'ladi.
  • Hisoblagichni joylashtirish qoidalarini buzish — muhrlash va tekshiruvlar bilan muammolar.
  • Bir chiziqli sxemaning yo'qligi — o'rnatuvchilar qurilmalar vazifasini bilmaydi, noto'g'ri ulanishlar paydo bo'ladi.
  • Metall qalqonni tuproqlamaslik — izolyatsiya shikastlanganda korpus kuchlanish ostida qoladi.

Elektr qalqoni haqida tez-tez beriladigan savollar

Modul nima va qalqon modulligini qanday aniqlash mumkin?

Modul — DIN-reykadagi en birligi: 1 modul = 17,5 mm. Barcha qurilmalar modullarini qo'shish kerak: 1P avtomat — 1 modul, 2P — 2, RCD 2P — 2, difavtomat — 2, hisoblagich — 4–8. So'ngra 15% zaxira qo'shiladi va standart qatordan qalqon tanlanadi: 18, 24, 36, 48 modul. Masalan, 3 xonali xonadon uchun odatda 24–36 modulli qalqon yetarli.

Nega aynan 15% zaxira?

PUE va IEC 61439 talabi: qalqonning bo'sh joylari kamida 15% bo'lishi kerak. Amalda har qanday uyda yangi zanjir qo'shiladi: konditsioner, suv isitgichi, unutilgan zaxira liniyasi. Zaxira bo'lmasa, qalqonni to'liq almashtirishga to'g'ri keladi — bu simlarni qayta tortish va o'nlab million so'm xarajat demakdir.

Qalqon issiqligini qanday hisoblash mumkin?

Qurilmalarning yo'qotish quvvatlarini qo'shish kerak: har avtomat qutbi nominal yuklamada taxminan 1–2 Vt, RCD — 1,5–3 Vt, hisoblagich — 2–5 Vt beradi. Aniq hisoblash Q = Σ I² × R formulasi bilan amalga oshiriladi (R — bo'shatish va kontaktlar qarshiligi, taxminan 0,5–2 mOm/qutb). Umumiy yo'qotish korpusning issiqlik o'tkazish qobiliyatidan (30–100 Vt) ortiq bo'lsa, kattaroq qalqon tanlang.

3 xonali xonadon uchun qaysi qalqonni tanlash kerak?

Standart sxema uchun: kirish 2P 40 A (2 modul), RCD 40 A/30 mA (2), yoritish avtomatlari 4 × 10 A (4), rozetka liniyalari 4 × 16 A (4), suv isitgichi difavtomati (2), plita liniyasi (2), hisoblagich (6–8). Jami taxminan 22–24 modul + 15% zaxira = 24–36 modulli qalqon. Ideal holda har xona liniyalari alohida belgilangan qalqon qabul qilinadi.

Metall va plastik qalqon o'rtasidagi farq nima?

Metall korpus mustahkam, yong'inga chidamli va majburiy tuproqlanadi — sanoat va umumiy foydalanish uchun standart. Plastik qalqon yengil, o'rnatish oson va xonadonlarda ishlatiladi, lekin yong'inga chidamliligi va mexanik mustahkamligi past. Zamonaviy xonadon qalqonlari ko'pincha metalldan tayyorlanadi — xavfsizlik nuqtai nazaridan ustun.

🔌 Barcha vositalar