-lg text-text-primary group-hover:text-brand transition-colors">GorkyCAD Pro
Bosh sahifa

Full material list in one click

Stop counting materials in Excel: GorkyCAD calculates cable length by routes, conduit, clips and dowels per meter, boxes, breakers and RCDs per groups, panel size, lights β€” with quantities and estimated prices.

πŸ“ Floor Plan & Rooms

🧱

Walls & Partitions

Load-bearing and non-load-bearing walls, partitions, thickness and material settings.

πŸšͺ

Doors & Windows

Door and window placement, size configuration, opening direction.

πŸ“

Dimensions & Annotations

Automatic dimensions, callouts, text annotations on the plan.

πŸ“¦

DXF Import

Import floor plans from AutoCAD and other CAD systems via DXF.

⚑ Electrical

Outlets & Switches

Power and low-current outlets, switches, dimmers. GOST/IS symbols.

πŸ’‘

Lighting

Luminaires, lighting groups, automatic illuminance calculation.

πŸ“«

Junction Boxes

Automatic junction box placement, connection count accounting.

πŸ“‹

GOST/PUE/IS Symbols

Complete library of symbols per GOST, PUE, IS, IEC standards.

πŸ”² Panels

πŸ—„οΈ

Auto Panel Assembly

Automatic panel layout: MCBs, RCDs, RCBOs, isolators β€” from the schematic.

πŸ“

DIN Rails & Busbars

Automatic DIN rail length calculation, auto busbars per phase.

🌐

Feeder Topology

Panel hierarchy: main β†’ sub β†’ floor β†’ apartment. Automatic connectivity.

〰️ Cables & Routes

πŸ—ΊοΈ

Auto Routing

Automatic cable routing via shortest path with obstacle avoidance.

πŸ“

Cable Sizing

Automatic cross-section calculation by heating, voltage drop, short-circuit current.

πŸ“Š

Cable Schedule

Automatic cable schedule generation with types, lengths, routes.

⬇️

Voltage Drop

Voltage drop calculation along the entire chain: from main panel to end consumer.

πŸ“Š Calculations

⚑

Loads

Pinst, Pcalc, Icalc, cos Ο†, Kd β€” automatic per IEC/IS standards.

πŸ”₯

Short-Circuit

Single-phase and three-phase short-circuit current calculation, breaker verification.

πŸ”—

Selectivity

Protection selectivity check: upstream/downstream breaker coordination.

Deterministic Engine

All calculations are deterministic, not LLM. Guaranteed repeatability.

πŸ“„ Documents

πŸ“‘

PDF Complete Set

Plan, single-line diagram, panel schematic, BOM, cable schedule, estimate β€” one click.

πŸ“

DXF Export

Export plans and schematics to DXF for compatibility with AutoCAD and other CAD.

πŸ“Š

Bill of Materials

Automatic bill of materials with equipment, cables and materials quantities.

πŸ’°

Estimate

Automatic cost calculation for equipment, cables, and installation work.

πŸ€– AI Assistant

βœ…

Standards Checking

Automatic project check against GOST, PUE, IS, IEC with violation details.

πŸ’‘

Recommendations

AI suggests fixes for errors and project optimizations.

Calculation Explanations

Step-by-step explanation of each calculation: formulas, inputs, results.

πŸ”

Project Search

Semantic project search: find all outlets in the bedroom, check cable size in the kitchen.

πŸ—οΈ 3D Visualization

3D Building Model

Automatic 3D building model from floor plan: walls, doors, windows.

3D Cable Routes

3D cable route visualization with color-coded groups.

πŸ—„οΈ

3D Panel

Three-dimensional panel visualization with DIN rails and devices.

And this is just the beginning. New features are added every week.

🌐 Open app πŸš€ Try for free

What is counted

  • Cable by cross-section and route (with 10% reserve);
  • Conduit and corrugation, clips and dowels;
  • Boxes, sockets, switches, lights;
  • Breakers, RCDs, panel size β€” per groups.

Ready to order

Export the list to Excel or PDF: positions, quantities, prices, totals. Take it to the shop or send to the supplier β€” nothing extra.

FAQ

Does the list include reserve?
Yes, 10% of cable and materials by default β€” you can change it.
What if the electrician changes the layout?
You edit the plan once β€” the list recalculates automatically.

Materiallar kalkulyatori

Elektr o'rnatish uchun materiallar miqdorini hisoblang: kabel uzunligi zaxira bilan, gofratrubka, qutilar, mahkamlagichlar β€” xonalar bo'yicha, PUE va SP 256 me'yorlariga muvofiq.

Kalkulyator nimani hisoblaydi

Materiallar miqdorini hisoblash o'rnatishni rejalashtirishning asosiy qismidir: material yetishmasa ish to'xtaydi, ortiqchasi esa pul yo'qotishdir. Kalkulyator kabel uzunligini marshrutlar bo'yicha, 10–15% zaxira qo'shilgan holda, gofratrubka, qutilar va mahkamlagichlar miqdorini hisoblaydi.

Hisoblash oddiy nisbatlarga asoslanadi: kabel uzunligi = gorizontal marshrutlar uzunligi + vertikal ko'tarilishlar (qavatga, rozetkalarga, o'chirgichlarga) + zaxira. Gofratrubka va kanallar kabel uzunligiga yaqin, qutilar esa ulanish nuqtalari soniga qarab olinadi.

Amaliy me'yorlar: rozetka yoki o'chirgich uchun balandlikka qarab 0,3–0,5 m kabel ko'tarilishi, har ulanish uchun 1 taqsimlash qutisi, har metr kabel uchun 2–3 mahkamlagich. Kalkulyator bularni avtomatik hisobga oladi.

Kalkulyatorning xususiyatlari

  • Kabel uzunligini marshrutlar bo'yicha hisoblash (10–15% zaxira bilan)
  • Gofratrubka va kabel kanallari miqdorini hisoblash
  • Taqsimlash qutilari va o'rnatish qutilari soni
  • Mahkamlagichlar va dublilar soni
  • Xonalar va qavatlar bo'yicha yig'ish
  • Qurilmalar sonini hisobga olish (rozetka, o'chirgich, lampa)
  • Materiallar ro'yxatini (BOM) tuzish

Hisoblash formulalari

Kabel uzunligi: L_kabel = Ξ£ L_marshrut Γ— (1 + K_zaxira/100), bunda K_zaxira = 10–15%, qo'shimcha ravishda har nuqtaga vertikal ko'tarilishlar: L_ko'tarilish = 0,3–0,5 m (rozetka/o'chirgich).

Umumiy uzunlik: L_umumiy = L_kabel + Ξ£ L_vertikal. Masalan, 30 m gorizontal marshrut va 12 nuqta uchun: L = 30 Γ— 1,1 + 12 Γ— 0,4 β‰ˆ 33 + 4,8 β‰ˆ 38 m.

Gofratrubka: L_truba β‰ˆ L_marshrut Γ— 1,05 (egilishlar uchun 5% zaxira). Kanallar: L_kanal = L_ochiq marshrut.

Qutilar: N_quti = N_ulanish + N_tarmoq; o'rnatish qutilari: N_orn = N_rozetka + N_o'chirgich. Mahkamlagichlar: N_mahkam β‰ˆ 2–3 Γ— L_kabel (har metrga).

L_kab = Ξ£ L_trassa Γ— 1,1–1,15; L_truba = L_kab Γ— 1,05; N_quti = N_nuqta; N_mahkam β‰ˆ 2–3/m

Materiallar me'yorlari jadvali

MaterialMe'yor
Kabel (devorda)Marshrut uzunligi Γ— 1,10–1,15
Gofratrubka / trubaKabel uzunligi Γ— 1,05
O'rnatish qutisi1 dona har nuqtaga
Taqsimlash qutisi1 dona har ulanishga
Mahkamlagichlar2–3 dona har metr kabelga
Avtomatlar, RCDQalqon sxemasi bo'yicha + 1 zaxira

Me'yoriy baza

Materiallarni hisoblash loyiha hujjatlarini tuzish qoidalariga β€” GOST 21.613-2014 Β«Elektr tarmoqlari ishchi hujjatlarini tuzish qoidalariΒ», SP 256.1325800.2016 va PUE talablariga muvofiq amalga oshiriladi. Asosiy me'yorlar:

β€” har o'rnatish nuqtasi uchun kabel ko'tarilish balandligi hisobga olinadi (rozetkalar uchun poldan 0,3 m, o'chirgichlar uchun 0,9–1,0 m);

β€” devorda yashirin yotqizish uchun gofratrubka yoki PVX truba majburiy (yonuvchan asoslar ustida);

β€” yonmaydigan kabel markasi (VVGng-LS) va yonmaydigan kabel o'tishlari talab qilinadi;

β€” materiallar miqdoriga texnologik yo'qotishlar uchun zaxira qo'shiladi (odatda 5–10%).

Kalkulyatordan qanday foydalanish kerak

  1. Ob'ektni tuzing: xonalar, qavatlar, har xonadagi nuqtalar ro'yxati.
  2. Har nuqtaning turini belgilang: rozetka, o'chirgich, lampa, konditsioner va h.k.
  3. Marshrutlar uzunligini kiriting yoki reja bo'yicha hisoblang.
  4. Zaxira foizini ko'rsating (standart 10–15%).
  5. Β«HisoblashΒ» tugmasini bosing va materiallar ro'yxati, umumiy uzunlik hamda narx taxminini oling.

Tez-tez uchraydigan xatolar

  • Zaxirasiz hisoblash β€” material yetishmaydi, ish to'xtaydi, qo'shimcha xarid uchun vaqt yo'qotiladi.
  • Vertikal ko'tarilishlarni unutish β€” qavat qalqoniga va rozetkalarga ko'tarilishlar uzunlikni sezilarli oshiradi.
  • Faqat to'g'ri marshrutlarni hisoblash β€” egilishlar, ulanishlar, taqsimlash qutilari unutiladi.
  • Mahkamlagichlar va sarf materiallarini unutish β€” ish joyida mayda qismlar tugaydi.
  • Birliklarni aralashtirish β€” metr va kilometr, dona va paketlar.
  • Qalqon komponentlarini unutish β€” avtomatlar, RCD, shinalar alohida hisoblanadi.

Materiallarni hisoblash haqida tez-tez beriladigan savollar

2 xonali xonadon uchun qancha kabel kerak?

Standart sxema uchun (yoritish + 15–20 rozetka nuqtasi) taxminan 200–300 m kabel talab qilinadi: 2,5 mmΒ² β€” rozetka liniyalari uchun 100–150 m, 1,5 mmΒ² β€” yoritish uchun 60–100 m. Aniq raqam reja konfiguratsiyasiga bog'liq β€” marshrutlar uzunligini o'lchang va 15% zaxira qo'shing.

Nega 10–15% zaxira kerak?

Real o'rnatishda marshrutlar har doim rejadagidan uzun bo'ladi: devor notekisligi, to'siqlar, qalqon ichidagi ko'tarilishlar, kesish chiqindilari. Bundan tashqari, kabel zaxirasi keyingi ta'mirlash va o'zgarishlar uchun foydali. 10–15% zaxira odatiy amaliy me'yor; murakkab ob'ektlarda 20% gacha oshiriladi.

Nuqtaga nima kiradi?

Nuqta β€” o'rnatish birligi: rozetka yoki o'chirgich uchun o'rnatish qutisi, unga boradigan kabel ko'tarilishi (0,3–0,5 m), ulanish va mahkamlash. Standart rozetka nuqtasi uchun materiallar: 1 o'rnatish qutisi, 0,4–0,6 m kabel 3Γ—2,5, 2–3 mahkamlagich, 1 rozetka qurilmasi. Konditsioner uchun alohida liniya tortiladi.

Gofratrubka uzunligini qanday baholash mumkin?

Gofratrubka deyarli har doim kabel marshrutiga teng tortiladi, lekin 5% zaxira qo'shiladi: burilishlar, ulanishlar, qalqonga ko'tarilish. Ya'ni 100 m kabel uchun taxminan 105 m gofratrubka kerak. Qayd: bitta gofratrubkada bir nechta kabel tortilishi mumkin β€” truba diametri kabellar soniga qarab tanlanadi (16, 20, 25 mm).

Kalkulyatorga qalqon komponentlari kiradimi?

Ha, alohida bo'lim sifatida: kirish avtomati, guruh avtomatlari, RCD, difavtomatlar, hisoblagich, DIN-reykalar, shinalar, terminallar. Qalqon sxemasini konstruktordan (panel-builder vositasi) olish mumkin va uning materiallar ro'yxati umumiy hisobga qo'shiladi. Har avtomat uchun 1 zaxira modul olish tavsiya etiladi.

πŸ”Œ Barcha vositalar