Elektromobil zaryadlash kalkulyatori

Elektromobilning istalgan stansiyadan zaryad vaqtini hisoblang: 230 V rozetka, Wallbox 3,7–22 kVt, tezkor DC-stansiyalar. Uy zaryad stansiyasi uchun avtomat, RCD (A turi) va kabelni tanlang.

Kalkulyator nimani hisoblaydi

  • Rozetka, Wallbox va tezkor stansiyadan to'liq zaryad vaqti
  • Fazalar bo'yicha zaryad toki (1 fazali va 3 fazali zaryad)
  • Uy zaryad stansiyasi uchun avtomat, A turidagi RCD va kabel kesimi
  • Uyning qoldiq quvvatini tekshirish (zaryad ajratilgan quvvatdan oshmaydimi)
  • Tarif bo'yicha zaryad narxi (kunduz/tun)
  • Zaryadlashdagi yo'qotishlar (zaryad qurilmasi FIK 85–90%)

Zaryad vaqtini qanday hisoblash kerak

Zaryad vaqti: t = E_batareya × (SoC_yakuniy − SoC_boshlang'ich) / (P_zaryad × η), bunda E — batareya sig'imi (kVt·soat), P — zaryad stansiyasi quvvati (kVt), η — bort zaryad qurilmasi FIK (AC-zaryad uchun 0,88–0,92, DC uchun 0,93–0,97).

Misol: Tesla Model Y (60 kVt·soat), 20→80% zaryad = 60 × 0,6 = 36 kVt·soat. Wallbox 11 kVt dan (3 fazali, η = 0,9): t = 36 / (11 × 0,9) = 3,6 soat. Rozetkadan 2,3 kVt: t = 36 / (2,3 × 0,9) = 17,4 soat.

Zaryad toki: I = P / (U × fazalar), 1 fazali 230 V uchun: 7,4 kVt → 32 A; 3 fazali 400 V uchun: 11 kVt → fazaga 16 A, 22 kVt → fazaga 32 A.

Toshkentda elektromobil infratuzilmasi jadal rivojlanmoqda: tezkor DC-stansiyalar va zaryadlash markazlari ko'paymoqda, biroq aksariyat egalar uchun asosiy zaryadlash joyi hali ham uydagi Wallbox hisoblanadi. Kundalik 40–60 km yo'l uchun 7,4 kVt bir fazali stansiya yetarli: 20→80% zaryad tunda 5–6 soat davom etadi. Kvartirada yashovchilar uchun ish joyidagi yoki savdo markazlaridagi stansiyalar ham muhim qo'shimcha variantdir.

Uy zaryad stansiyasiga me'yoriy talablar

Zaryad stansiyasi (EVSE) o'rnatilishi PUE (7.1-bob), СП 256.1325800 (14.37–14.42-bandlar), GOST R 58619-2019 va GOST 33672-2015 bilan tartibga solinadi. Talablar:

— qalqondan zaryad stansiyasiga o'z avtomati bilan alohida liniya;

— A turidagi RCD (pulsatsiyalanuvchi o'zgarmas tok) 30 mA majburiy;

— yonmaydigan izolyatsiyali kabel (VVGng-LS), kesimi hisobiy tok bo'yicha: 3,7 kVt/16 A — 2,5 mm²; 7,4 kVt/32 A — 6 mm²; 11 kVt/16 A (3f) — 5×2,5 mm²; 22 kVt/32 A (3f) — 5×6 mm²;

— TN-C-S tizimi bo'yicha yerga ulash, kirishda takroriy yerga ulash;

— ko'p qavatli uylarda 3,7 kVt dan yuqori quvvat uchun boshqaruv kompaniyasi bilan kelishish va ajratilgan quvvatni tekshirish.

Yevropa Ittifoqida IEC 61851 standarti, AQShda NEC 625 amal qiladi; ko'pchilik mamlakatlarda AC uchun Type 2 (Mennekes), DC uchun CCS Combo 2 quvvat rozetkasi majburiy.

Zaryad tezliklari jadvali

Zaryad turiQuvvatTokSoatiga km (18 kVt·soat/100 km sarf)Tipik qo'llanilishi
230 V rozetka (Type F/G)1,4–2,3 kVt6–10 A8–12 km/soatFavqulodda, tungi
Wallbox 1 fazali3,7 kVt16 A18–20 km/soatUy, tun
Wallbox 1 fazali maks.7,4 kVt32 A35–40 km/soatUy, kunduz
Wallbox 3 fazali11 kVt16 A/faza55–60 km/soatUy/ofis, tun
Wallbox 3 fazali maks.22 kVt32 A/faza110–120 km/soatOfis, tijorat
Tezkor DC50 kVtDC250–280 km/soatYo'l
Ultra tezkor DC150–350 kVtDC1000+ km/soat gachaYo'l, markazlar

Kalkulyatordan qanday foydalanish kerak

  1. Ro'yxatdan elektromobil modelini tanlang yoki batareya sig'imini qo'lda kiriting.
  2. Zaryad darajasini oldin va keyin ko'rsating (standart 20→80% — ishlab chiqaruvchilar tavsiyasi).
  3. Zaryad turini tanlang: rozetka, Wallbox 3,7/7,4/11/22 kVt yoki tezkor DC-stansiya.
  4. Uy stansiyasi uchun uyning ajratilgan quvvatini ko'rsating (masalan 15 kVt) — kalkulyator zaxirani tekshiradi.
  5. «Hisoblash» tugmasini bosing — zaryad vaqti, tok, avtomat, RCD, kabel, narx.

Tez-tez uchraydigan xatolar

  • Rozetkadan 7,4 kVt zaryadlash — standart rozetka maksimum 16 A ga mo'ljallangan; 32 A alohida liniya talab qiladi.
  • A turi o'rniga AC turidagi RCD — zaryad qurilmalari pulsatsiyalanuvchi o'zgarmas sizib chiqish toki hosil qiladi, AC turi uni ko'rmaydi.
  • Uch fazali tarmoqda ikki fazali yuk — fazalar og'ishi, tarmoqning notekis eskirishi.
  • Zaryad FIK ini hisobga olmaslik — real vaqt «toza» hisobdan 10–15% ko'p.
  • Har kuni 100% gacha zaryadlash — LFP va NMC batareyalarning tezlashtirilgan degradatsiyasi; optimal 20–80%.

Elektromobil zaryadlash haqida tez-tez beriladigan savollar

Elektromobil uy rozetkasidan qancha vaqt zaryadlanadi?

Oddiy 2,3 kVt rozetkadan — 50–80 kVt·soat batareya uchun 12–20 soat (20→80% zaryad). Bu faqat tungi zaryad uchun amaliy. Kunlik sayohatlari bo'lgan uy uchun Wallbox 7,4–11 kVt tavsiya etiladi: tunda 4–6 soat.

11 kVt zaryad stansiyasi uchun qanday avtomat kerak?

Uch fazali 11 kVt (400 V) uchun: fazaga 16 A tok, C16 (3P) avtomati, A turidagi RCD 30 mA, 5×2,5 mm² kabel. 1 fazali 7,4 kVt uchun: 1P C32 avtomati, A turidagi RCD, 3×6 mm² kabel.

Elektromobilni har kuni zaryadlash mumkinmi?

Ha, elektromobillar aynan shu uchun mo'ljallangan. Optimal rejim: zaryadni 20–80% oralig'ida ushlab turish (LFP uchun davriy kalibrlash bilan 100% ruxsat etiladi), 10% dan past chuqur zaryadsizlanishga yo'l qo'ymaslik.

Qaysi qimmatroq — uyda yoki tezkor stansiyalarda zaryadlash?

Uyda tungi tarif (taxminan 300 so'm/kVt·soat) bilan zaryadlash tezkor stansiyalardan (1200–1500 so'm/kVt·soat) 3–5 barobar arzon. Yiliga 15 000 km da farq 2,5–3,5 million so'mni tashkil qiladi. Tezkor stansiyalar — uzoq safarlar uchun.

Xonadonda Wallbox o'rnatish uchun ruxsat kerakmi?

Bo'sh quvvat mavjud bo'lsa, 3,7 kVt gacha zaryad stansiyasi — СП 256.1325800 bo'yicha xabarnoma tartibi. 3,7 kVt dan yuqori quvvat boshqaruv kompaniyasi bilan kelishish va uyning ajratilgan quvvatini tekshirishni talab qiladi. Yangi qurilishlarda zaryad stansiyalari ko'pincha loyihada nazarda tutiladi.

🔌 Barcha vositalar

(function(){ var T={ az:{t:"Elektromobil doldurma kalkulyatoru",bat:"Batareya tutumu (kVt·с)",so:"Başlanğıc yükü (%)",so2:"Son yük (%)",type:"Doldurma növü",sock:"Rozetka 2.3 kVt",w7:"Wallbox 7.4 kVt",w11:"Wallbox 11 kVt",w22:"Wallbox 22 kVt",dc:"Sürətli DC 50 kVt",calc:"Hesabla",res:"Nəticə",time:"Doldurma vaxtı",cur:"Cərəyan",brk:"Avtomat",rcd:"UZO tip A 30 mA",cable:"Kabel",cost:"Qiymət",note:"Hesablama η=0.9"}, be:{t:"Калькулятар зарадкі электрамабіля",bat:"Ёмістасць батарэі (кВт·гадз)",so:"Пачатковы зарад (%)",so2:"Канчатковы зарад (%)",type:"Тып зарадкі",sock:"Разетка 2.3 кВт",w7:"Wallbox 7.4 кВт",w11:"Wallbox 11 кВт",w22:"Wallbox 22 кВт",dc:"Хуткая DC 50 кВт",calc:"Разлічыць",res:"Вынік",time:"Час зарадкі",cur:"Ток",brk:"Аўтамат",rcd:"УЗО тып A 30 мА",cable:"Кабель",cost:"Кошт",note:"Разлік η=0.9"}, de:{t:"Ladezeitrechner E-Auto",bat:"Batteriekapazität (kWh)",so:"Start-SoC (%)",so2:"Ziel-SoC (%)",type:"Ladeart",sock:"Steckdose 2.3 kW",w7:"Wallbox 7.4 kW",w11:"Wallbox 11 kW",w22:"Wallbox 22 kW",dc:"Schnell-DC 50 kW",calc:"Berechnen",res:"Ergebnis",time:"Ladezeit",cur:"Strom",brk:"Sicherung",rcd:"RCD Typ A 30 mA",cable:"Kabel",cost:"Kosten",note:"Berechnung η=0.9"}, en:{t:"EV Charging Calculator",bat:"Battery capacity (kWh)",so:"Start SoC (%)",so2:"Target SoC (%)",type:"Charging type",sock:"Socket 2.3 kW",w7:"Wallbox 7.4 kW",w11:"Wallbox 11 kW",w22:"Wallbox 22 kW",dc:"Fast DC 50 kW",calc:"Calculate",res:"Result",time:"Charging time",cur:"Current",brk:"Breaker",rcd:"RCD type A 30 mA",cable:"Cable",cost:"Cost",note:"Calculation η=0.9"}, hi:{t:"EV चार्जिंग कैलकुलेटर",bat:"बैटरी क्षमता (kWh)",so:"स्टार्ट SoC (%)",so2:"टार्गेट SoC (%)",type:"चार्जिंग प्रकार",sock:"सॉकेट 2.3 kW",w7:"वॉलबॉक्स 7.4 kW",w11:"वॉलबॉक्स 11 kW",w22:"वॉलबॉक्स 22 kW",dc:"फास्ट DC 50 kW",calc:"गणना करें",res:"परिणाम",time:"चार्जिंग समय",cur:"करंट",brk:"MCB",rcd:"RCD टाइप A 30 mA",cable:"केबल",cost:"लागत",note:"गणना η=0.9"}, hy:{t:"Էլեկտրամոբիլի լիցքավորման հաշվիչ",bat:"Մարտկոցի տարողություն (կՎտ·ժ)",so:"Սկզբնական SoC (%)",so2:"Վերջնական SoC (%)",type:"Լիցքավորման տեսակ",sock:"Վարդակ 2.3 կՎտ",w7:"Wallbox 7.4 կՎտ",w11:"Wallbox 11 կՎտ",w22:"Wallbox 22 կՎտ",dc:"Արագ DC 50 կՎտ",calc:"Հաշվել",res:"Արդյունք",time:"Լիցքավորման ժամանակ",cur:"Հոսանք",brk:"Ավտոմատ",rcd:"ՈՒԶՕ տիպ A 30 մԱ",cable:"Մալուխ",cost:"Արժեք",note:"Հաշվարկը η=0.9"}, ka:{t:"ელექტრომობილის დატენვის კალკულატორი",bat:"ბატარეის მოცულობა (კვტ·სთ)",so:"საწყისი SoC (%)",so2:"სამიზნე SoC (%)",type:"დატენვის ტიპი",sock:"სოკეტი 2.3 კვტ",w7:"Wallbox 7.4 კვტ",w11:"Wallbox 11 კვტ",w22:"Wallbox 22 კვტ",dc:"სწრაფი DC 50 კვტ",calc:"გამოთვლა",res:"შედეგი",time:"დატენვის დრო",cur:"დენი",brk:"ავტომატი",rcd:"უიზო ტიპი A 30 მა",cable:"კაბელი",cost:"ფასი",note:"გამოთვლა η=0.9"}, kk:{t:"Электромобильді зарядтау калькуляторы",bat:"Батарея сыйымдылығы (кВт·сағ)",so:"Бастапқы SoC (%)",so2:"Соңғы SoC (%)",type:"Зарядтау түрі",sock:"Розетка 2.3 кВт",w7:"Wallbox 7.4 кВт",w11:"Wallbox 11 кВт",w22:"Wallbox 22 кВт",dc:"Жылдам DC 50 кВт",calc:"Есептеу",res:"Нәтиже",time:"Зарядтау уақыты",cur:"Ток",brk:"Автомат",rcd:"УЗО тип A 30 мА",cable:"Кабель",cost:"Бағасы",note:"Есептеу η=0.9"}, ky:{t:"Электромобилди кубаттоо калькулятору",bat:"Батареянын сыйымдуулугу (кВт·с)",so:"Баштапкы SoC (%)",so2:"Акыркы SoC (%)",type:"Кубаттоо түрү",sock:"Розетка 2.3 кВт",w7:"Wallbox 7.4 кВт",w11:"Wallbox 11 кВт",w22:"Wallbox 22 кВт",dc:"Тез DC 50 кВт",calc:"Эсептөө",res:"Жыйынтык",time:"Кубаттоо убактысы",cur:"Ток",brk:"Автомат",rcd:"УЗО тип A 30 мА",cable:"Кабель",cost:"Баасы",note:"Эсептөө η=0.9"}, pl:{t:"Kalkulator ładowania EV",bat:"Pojemność baterii (kWh)",so:"Początkowy SoC (%)",so2:"Docelowy SoC (%)",type:"Typ ładowania",sock:"Gniazdo 2.3 kW",w7:"Wallbox 7.4 kW",w11:"Wallbox 11 kW",w22:"Wallbox 22 kW",dc:"Szybkie DC 50 kW",calc:"Oblicz",res:"Wynik",time:"Czas ładowania",cur:"Prąd",brk:"Wyłącznik",rcd:"RCD typ A 30 mA",cable:"Kabel",cost:"Koszt",note:"Obliczenia η=0.9"}, ro:{t:"Calculator încărcare EV",bat:"Capacitate baterie (kWh)",so:"SoC inițial (%)",so2:"SoC țintă (%)",type:"Tip încărcare",sock:"Priza 2.3 kW",w7:"Wallbox 7.4 kW",w11:"Wallbox 11 kW",w22:"Wallbox 22 kW",dc:"Rapid DC 50 kW",calc:"Calculează",res:"Rezultat",time:"Timp încărcare",cur:"Curent",brk:"Întrerupător",rcd:"RCD tip A 30 mA",cable:"Cablu",cost:"Cost",note:"Calcul η=0.9"}, ru:{t:"Калькулятор зарядки электромобиля",bat:"Ёмкость батареи (кВт·ч)",so:"Начальный заряд (%)",so2:"Конечный заряд (%)",type:"Тип зарядки",sock:"Розетка 2.3 кВт",w7:"Wallbox 7.4 кВт",w11:"Wallbox 11 кВт",w22:"Wallbox 22 кВт",dc:"Быстрая DC 50 кВт",calc:"Рассчитать",res:"Результат",time:"Время зарядки",cur:"Ток",brk:"Автомат",rcd:"УЗО тип A 30 мА",cable:"Кабель",cost:"Стоимость",note:"Расчёт η=0.9"}, tg:{t:"Калкулятори пур кардани электромобил",bat:"Иқтидори батарея (кВт·с)",so:"Саршавии SoC (%)",so2:"SoC-и ниҳоӣ (%)",type:"Навъи пуркунӣ",sock:"Розетка 2.3 кВт",w7:"Wallbox 7.4 кВт",w11:"Wallbox 11 кВт",w22:"Wallbox 22 кВт",dc:"Зуд DC 50 кВт",calc:"Ҳисоб кардан",res:"Натиҷа",time:"Вақти пуркунӣ",cur:"Ҷараён",brk:"Автомат",rcd:"УЗО навъи A 30 мА",cable:"Кабел",cost:"Нарх",note:"Ҳисоб η=0.9"}, uz:{t:"Elektromobil quvvatlash kalkulyatori",bat:"Batareya sig'imi (kVt·s)",so:"Boshlang'ich SoC (%)",so2:"Yakuniy SoC (%)",type:"Quvvatlash turi",sock:"Rozetka 2.3 kVt",w7:"Wallbox 7.4 kVt",w11:"Wallbox 11 kVt",w22:"Wallbox 22 kVt",dc:"Tez DC 50 kVt",calc:"Hisoblash",res:"Natija",time:"Quvvatlash vaqti",cur:"Tok",brk:"Avtomat",rcd:"UZO turi A 30 mA",cable:"Kabel",cost:"Narxi",note:"Hisoblash η=0.9"} }; var L=document.documentElement.lang;var t=T[L]||T.en; var S=document.createElement('div'); S.innerHTML='

'+t.t+'

'+ '
'+ '
'+ '
'+ '
'+ '
'+ '
'+ ''+ '
'; var h=document.querySelector('main');if(!h)return;var sect=h.querySelector('.section');if(!sect)return;sect.parentNode.insertBefore(S,sect.nextSibling); document.getElementById('ev-go').onclick=function(){ var E=+document.getElementById('ev-bat').value; var s1=+document.getElementById('ev-so').value/100; var s2=+document.getElementById('ev-so2').value/100; var P=+document.getElementById('ev-type').value; var eta=P>=50?0.95:0.9; var kWh=E*(s2-s1); var th=kWh/(P*eta); var hh=Math.floor(th),mm=Math.round((th-hh)*60); var I=P<50?(P/230):(P/692); var brk=I>32?63:(I>25?40:(I>15?32:(I>10?20:16))); var sec=I>25?'6 mm²':(I>15?'4 mm²':'2.5 mm²'); var ph=P>=50?'DC':(P>=11?'3-ph':'1-ph'); var price=+document.getElementById('ev-kwh').value; var cost=kWh*price; var km=Math.round(kWh/18*100); var o=''+t.res+'
'+t.time+': '+hh+' ч '+String(mm).padStart(2,"0")+' мин ('+kWh.toFixed(1)+' kWh · +'+km+' км)
'; if(P<50)o+=t.cur+': '+I.toFixed(0)+' A ('+ph+') · '+t.brk+': C'+brk+' · '+t.cable+': '+sec+'
'+t.rcd+'
'; o+=(price>0?t.cost+': '+cost.toFixed(0)+' ₽
':'')+''+t.note+''; document.getElementById('ev-out').innerHTML=o; };})();