← All tools

Electrical Load Calculator

A professional tool for collecting and calculating electrical loads in residential and commercial buildings. The calculator sums up the installed power of all loads, applies demand and coincidence factors per international standards, and computes the design current.

Supports per-phase load distribution for three-phase networks — you can see the current on each phase, identify imbalance, and adjust the distribution of electrical loads accordingly.

Features

  • Floor-by-floor and room-by-room load collection
  • Installed and design power calculation (kW/kVA)
  • Demand factor (Kd) and coincidence factor (Kc) application
  • Per-phase current calculation (L1, L2, L3)
  • Phase imbalance detection
  • Load schedule export to PDF/Excel
  • Power supply reliability category determination

Standards

  • IEC 60364 — Low-voltage electrical installations
  • SP 256.1325800 — Electrical equipment of residential and public buildings
  • IS 732 — Indian standard for electrical wiring installations

Frequently asked questions

What is the demand factor Kc?

Kc is the ratio of calculated to installed power — not all devices run at once. For a single dwelling Kc = 1.0, for groups of apartments 0.5–0.9 (SP 256.1325800 / IEC).

When do I need 3-phase?

When the calculated load exceeds 10 kW. Phase current drops by √3: 12 kW = 17.3 A per phase at 400 V.

Why Kc = 1 for one apartment?

All installed devices in a single dwelling can run simultaneously, so the calculated load equals the installed one.

How to calculate the main current?

I = P/(√3·U·cosφ) for 3-phase, I = P/(U·cosφ) for 1-phase. 10 kW at 230 V ≈ 43 A — you need a 40–50 A supply.

Cálculo de cargas elétricas

Some a potência dos receptores, aplique o fator de demanda e obtenha a potência demandada, a corrente e a entrada recomendada.

O que calcula

  • Potência instalada: soma dos receptores
  • Potência demandada: instalada × Kc
  • Corrente: 230 V ou 400 V
  • Potência de entrada recomendada

Fator de demanda Kc

Kc = relação entre potência demandada e instalada. Para uma residência individual Kc = 1,0; para grupos de unidades 0,5–0,9.

Normas

  • NBR 5410 — previsão de cargas
  • REBT ITC-BT-10
  • NEC 220

FAQ

O que é o fator de demanda?

Indica qual parte da potência instalada funciona simultaneamente. Residência individual: 1,0.

Quando usar trifásico?

Quando a demanda supera 10 kW — a corrente por fase cai √3 vezes.

Como calcular a potência contratada?

Arredonde a demanda para o escalão comercial (4,6/5,75/6,9/9,2/11,5 kVA no Brasil).

🔌 Todas as ferramentas