← All tools

Electrical Load Calculator

A professional tool for collecting and calculating electrical loads in residential and commercial buildings. The calculator sums up the installed power of all loads, applies demand and coincidence factors per international standards, and computes the design current.

Supports per-phase load distribution for three-phase networks — you can see the current on each phase, identify imbalance, and adjust the distribution of electrical loads accordingly.

Features

  • Floor-by-floor and room-by-room load collection
  • Installed and design power calculation (kW/kVA)
  • Demand factor (Kd) and coincidence factor (Kc) application
  • Per-phase current calculation (L1, L2, L3)
  • Phase imbalance detection
  • Load schedule export to PDF/Excel
  • Power supply reliability category determination

Standards

  • IEC 60364 — Low-voltage electrical installations
  • SP 256.1325800 — Electrical equipment of residential and public buildings
  • IS 732 — Indian standard for electrical wiring installations

Frequently asked questions

What is the demand factor Kc?

Kc is the ratio of calculated to installed power — not all devices run at once. For a single dwelling Kc = 1.0, for groups of apartments 0.5–0.9 (SP 256.1325800 / IEC).

When do I need 3-phase?

When the calculated load exceeds 10 kW. Phase current drops by √3: 12 kW = 17.3 A per phase at 400 V.

Why Kc = 1 for one apartment?

All installed devices in a single dwelling can run simultaneously, so the calculated load equals the installed one.

How to calculate the main current?

I = P/(√3·U·cosφ) for 3-phase, I = P/(U·cosφ) for 1-phase. 10 kW at 230 V ≈ 43 A — you need a 40–50 A supply.

Cálculo de cargas eléctricas

Suma la potencia de todos los receptores de la vivienda, aplica el factor de simultaneidad y obtén la potencia demandada, la corriente y la potencia de entrada recomendada.

Qué calcula

  • Potencia instalada: suma de todos los receptores
  • Potencia demandada: instalada × Kc
  • Corriente: monofásica 230 V o trifásica 400 V
  • Potencia de entrada recomendada (contrato de suministro)

Factor de simultaneidad Kc

Kc es la relación entre la potencia demandada y la instalada — no todos los aparatos funcionan a la vez. Para una vivienda individual Kc = 1,0; para grupos de viviendas 0,5–0,9 (REBT ITC-BT-10 / IEC).

Normas

  • REBT ITC-BT-10 — previsión de cargas (España)
  • IEC 60364-4-44 — coordinación de cargas
  • NOM-001-SEDE, sección 220 (México)

FAQ

¿Qué es el factor de simultaneidad?

Indica qué parte de la potencia instalada funciona a la vez. Una vivienda: 1,0. Varias viviendas: 0,5–0,9 según el número.

¿Cuándo se necesita trifásica?

Cuando la potencia demandada supera 10 kW (REBT ITC-BT-10). La corriente por fase baja √3 veces: 12 kW = 17,3 A/fase a 400 V.

¿Cómo calcular la potencia contratada?

Redondea la potencia demandada al escalón comercial (por ejemplo 4,6/5,75/6,9/9,2/11,5 kW en España). Para una vivienda media 5,75–9,2 kW.

🔌 Todas las herramientas